Diagram shows
minimum
clearances from
combustible
materials

qualified service technician to inspect
the room heater and to replace any part
of the control system and any gas control
which has been under water.

16 Adequate clearances for accessibility for

purposes of servicing and proper
operation should be provided.

17 Adequate clearances around air

openings into the combustion chamber
should be provided.

18 Do not install in areas where curtains,

drapes, clothing, or other moving
flammables are within 15 inches of this
unit.

23 The draft hood on the appliance should

be installed in the same atmospheric
pressure zone as the combustion air inlet
to the appliance and shall be located so
that the relief opening is accessible for
checking vent operation.

24 The appliance, when installed, must be

electrically grounded in accordance with
local codes or, in the absence of local
codes, with the National Electrical
Code, ANSI/NFPA 70
, or the Canadian
Electrical Code, CSA C22.1

25 A gas appliance must not be connected

to a chimney flue serving a solid fuel
burning appliance.

26 Do not restrict the warm air discharge

by placing articles in front of heater.

27 This appliance must not be used for any

purpose other than heating.

28 Do not allow anyone to post articles

through the louvres.

29 Do not allow anyone to sit or lean

against the appliance.

30 DUE TO HIGH TEMPERATURES, THE

APPLIANCE SHOULD BE LOCATED
OUT OF TRAFFIC AND AWAY FROM
FURNITURE AND DRAPERIES.

31 CHILDREN AND ADULTS SHOULD BE

ALERTED TO THE HAZARDS OF
HIGH SURFACE TEMPERATURES
AND SHOULD STAY AWAY TO AVOID
BURNS OR CLOTHING IGNITION.

32 CLOTHING OR OTHER FLAMMABLE

MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.

33 INSTALLATION AND REPAIR SHOULD

BE DONE BY A QUALIFIED SERVICE
PERSON. THE APPLIANCE SHOULD
BE INSPECTED BEFORE USE AND
AT LEAST ANNUALLY BY A
PROFESSIONAL SERVICE PERSON.
MORE FREQUENT CLEANING MAY
BE REQUIRED DUE TOO
EXCESSIVE LINT FROM CARPETING

19 Periodic examination of the venting

system is required.

20 The flow of combustion and ventilation

air should not be obstructed.

21 A manufactured home (USA only) or

mobile home OEM installation must
conform with the Manufactured Home
Construction and Safety Standard, Title
24CFR, Part 3280
, or, when such a
standard is not applicable, the Standard
for Manufactured Home Installations,
ANSI/NCSBCS A225.1
or Standard for
Gas Equipped Recreational Vehicles
and Mobile Housing, CSA Z240.4.

22 The appliance and its appliance main

gas valve must be disconnected from the
gas supply piping system during any
pressure testing of that system at test
pressures in excess of 1/2 psi (3.5 kPa).

The appliance must be isolated from the
gas supply piping system by closing its
equipment shutoff valve during any
pressure testing of the gas supply piping
system at pressures equal to or less than
½ psi (3.5 kPa).

12”
RIGHT

36”
CEILING

36”
FRONT

12”
LEFT