If the SELF HELP checks do not cover the symptom, you should seek professional help.

The following additional checklist is provided for the benefit of the qualified engineer.

WARNING: SWITCH OFF THE ELECTRICITY AT THE ISOLATING SWITCH BEFORE REMOVING
THE COVER TO MAKE CHECKS.

Table 2

a) Unit fails to heat the water

Check that the water supply is on and that its pressure is
between 0.7 Bar 69kPa (10 psi) and 10.0 Bar 940 kPa (140 psi).

Check circuit through solenoid coil.

Check circuit through the heating element.

Check circuit through float switch.

If defective then replace.

b) All the lights are out and the

POWER button does not work

Ensure that the electricity supply is switched on at the isolator.

Ensure that the flying lead to the front cover is connected
properly (see Fig. 5a and Fig. 5b).

Check the supply to the PCB. If supply OK then change PCB.

c) Water flows continuously

from the steam vent pipe

Check that the float switch operates correctly and switches the
water solenoid on and off.

d) The water tank takes more

than 20 minutes to fill with
water

CONDITION

SB

2

is switched on at the local

isolator and the unit is empty
of water.

POWER button is pressed.

SB

2

is switched on at the local

isolator and the unit is already
full of cold water.

POWER button is pressed.

APPROXIMATE HEAT UP TIME

2.5 Litre SB

2

4 Litre SB

2

12 minutes

18 minutes

(4 mins filling

(5 mins filling

8 mins heating)

13 mins heating)

8 minutes

13 minutes

WHAT ELSE HAPPENS

- POWER light comes on
- then FULL light comes on
- then TEMPERATURE READY

light comes on

- then steam comes out of

the vent for 30 seconds.

- POWER and FULL lights

both come on.

- then TEMPERATURE READY

light comes on.

- then Steam comes out of

the vent for 30 seconds

Check that the water supply is on and that its pressure is
between 0.7 Bar 69kPa (10 psi) and 10.0 Bar 940kPa (140 psi).

Check operation of the water solenoid and that water flows
into the tank at a rate between 0.3 Litres/min and 1 Litre/min.

Check circuit through the solenoid coil.