Fixing the unit on the wall

● Use the wall mounting bracket supplied and the two lower fixing holes.
● An extra top fixing point is available by temporarily removing the condenser assembly.

Connecting the water supply and vent pipes

● When the unit is fixed to the wall, make the final water supply and steam vent connections

and secure the pipe work.

● Switch the water supply back on.

Connecting the mains cable

● Ensure the mains supply is isolated.
● Connect the mains cable from the SB

2

to the 13 Amp fused isolating switch. Ensure

the cable clamps are firmly secured and the cable ends are tightened into the terminal block.

Note: The supply cable must be a minimum of 1.0mm

2

three core multi strand PVC insulated

mains cable. The terminal block will not accept cable diameters above 1.5mm

2

. Check that the

mains supply matches the electrical rating on the product. The rating plate is located on the
bottom edge of the unit.

IMPORTANT: Connect the supply cable, complying with BS6500, to this appliance in accordance
with the following code:

GREEN AND YELLOW (EARTH) connect to terminal marked " ".
BLUE (NEUTRAL) connect to terminal marked "N"
BROWN (LIVE) connect to terminal marked "L"

WARNING: THIS APPLIANCE, AND ALL METAL PIPE WORK CONNECTED TO IT, MUST BE
EARTHED.

Replacing the front cover

● Support the cover and re-attach the flying lead to the unit (See Fig. 5a and Fig. 5b).
● Replace the front cover and secure using the top and bottom fixing screws.
● Carefully replace the knob, ensuring correct alignment of the D shaft.
● Reconnect the mains supply.

Schematic
Wiring
Diagram