How to clean and descale your sb, Descaling – Redring CD-RW901SL User Manual

Page 8

Advertising
background image

Please Note:
● The SB

2

can take several minutes to reach the required temperature, depending on usage

and tank capacity.

● To avoid energy wastage, the SB

2

will automatically reduce the temperature by 10 ºC if the

unit is not used for more than 60 minutes. (The SB

2

will automatically go back to boiling

when the water is used).

● When the SB

2

is switched on at the local isolator and the POWER button is pressed, it will

start by self calibrating. This can take up to 20 minutes to complete and includes
automatically boiling the water for 30 seconds.

When first installed, it is recommended that the initial tank of boiling water is fully

drawn off and discarded. Allow the tank to re-fill and the TEMPERATURE READY light to
come on, before using the SB

2

.

Dispensing water from the SB

2

● Place your cup under the red spout at the bottom of the unit.
● Turn the knob clockwise to fill your cup (Fig. 7b).
● Turn the knob anti-clockwise to OFF (Fig. 7a).

WARNING

SCALDING HOT WATER can be dispensed from the SB

2

.

Never wash your hands directly from the unit.
Some plastic cups can distort if they are filled with boiling water, so causing a danger

of scalding.

How to clean and descale your SB

2

● Before cleaning or descaling, switch off the electricity at the isolating switch.
● It is recommended that the SB

2

surfaces are cleaned with a soft cloth.

Do not use abrasive or solvent cleaning fluids.

DESCALING

A qualified electrician should carry out the descaling.
ENSURE THE MAINS ELECTRICITY SUPPLY IS ISOLATED.

If scale comes out with the hot water then the SB

2

may need to be descaled. This is

done by removing the front cover and top condenser assembly and using a suitable
kettle descaler. Ensure unit is thoroughly flushed through after descaling.

8

Fig. 7b

Fig. 7a