Set the desired room temperature, Time limited settings, Hysteresis – Optima Company 600 - 1700 User Manual

Page 21: Time control

Advertising
background image

21

Advanced menu

Hysteresis

Hysteresis settings can be made under Heating system temperature. The
hysteresis determines when the heat pump (compressor) is to start/stop in
relation to the heat curve’s value. The compressor continues slightly longer
than according to the curve and starts again when the fl ow temperature has
dropped somewhat below the value of the curve. In this way, the heat pump
is prevented from starting and stopping continuously.

There is usually no reason to adjust the hysteresis factory settings or those
having been set by the installer.

Set the desired room temperature

If you have a room sensor connected to the heat pump you can set the
required temperature in the room from the Room sensor settings menu. This
is carried out in the same way as in Menu (initial menu).

You can also set how much the sensor is to affect the heating system by
selecting Room sensor infl uence and adjusting the Change factor. Min = 0,
max = 10. A higher factor gives a greater infl uence from the room sensor.

After a heat lowering period, e.g. time control or holiday, the room sensor
infl uence is blocked for a set time, factory setting is 4 hours. Min = 0 and
max = 24 hours. The function Blocking time is under Room sensor infl uence
and means that the heat pump is given time to increase the fl ow tempera-
ture more slowly than if the room sensor is allowed to infl uence.

Time limited settings

Time control

The Time control heating function can be used to lower or increase the
temperature on different week days at chosen times.

1. Select

Time control heating

in the menu Time limited settings under

Temperature

.

2. Select

Day and time

.

3. Enter the week day and the time at which time control is to occur.

Select On.

4. Select

Save

to save the change or Cancel to return without saving.

5. Select

Change in temperature

and set the desired value.

Min = -20ºC, max = +20ºC.

6. Select

Save

to save the change or Cancel to return without saving.

To remove a time control setting, fi nd the desired setting and select Off.

Time control is not recommended
in normal conditions as it can affect
consumption negatively.

Note