Communication failures -4, Communication failures, Error 06 – micropositioner location unknown – Oce North America LIGHTJET 500XL User Manual

Page 20: Error 07 – media guide stuck at home, Error 10 – outfeed timeout fault

Advertising
background image

LightJet 500XL Maintenance Guide

×

see copyright, disclosure, use and duplication information on pg ii

48058-A

3-4

Error 06 – Micropositioner Location Unknown

Possible
Cause:

Micropositioner has lost servo.

Recovery
Method:

Select Media/Cut and Unload. If problem persists, contact Océ.

Error 07 – Media Guide Stuck at Home

Possible
Causes:

A) Media guides are stuck in their parked position.

B) Mechanical component failure.

Recovery
Methods:

A) Select Media/Cut and Unload. Inspect media guides. Clear physical

obstruction if present.

B) Contact Océ.

Error 10 – Outfeed Timeout Fault

Possible
Cause:

The bottom-of-drum sensor did not sense any media within 30 seconds.

Recovery
Method:

Select Set Up/Motor Control/All Motors Reverse. Retract 150 inches of media.
If error persists, contact Océ.

Communication Failures

Problems that prevent proper communication between the LightJet

®

500XL and the host

computer can cause total loss of communication, prevent certain functions, or corrupt the data
used to generate the image. The LightJet

®

500XL cannot detect:

§ Whether the host computer is unable to generate the proper commands.

§ Some cases of data corruption.

1

§ When a SCSI cable is bad or disconnected.

§ When the wrong SCSI ID has been selected.

2

Notes:

1

The LightJet 500XL can detect some, but not all, types of data corruption.

2

The LightJet 500XL is shipped from the factory with the SCSI ID set to 6 (binary 110).

Advertising