OMEGA FP-5060 Series Micro Flow Sensor

4. Fitting

Installation

CAUTION:
• Maximum pipe fi tting torque: 10 ft - lbs (13 N m).
• DO NOT overtighten. Failure to observe torque specifi cation may permanently damage sensor ports.

5. Calibration

The K-Factors listed below represent the number of pulses the sensor will generate for each engineering unit of fl uid which passes.
They are listed in U.S. gallons, liters and mL by sensor model:

Technical Notes:

Compatible fi ttings (customer supplied): Female union (shown), reducer, or hose barb type.

Always apply thread sealant to sensor port threads to prevent leakage.

Sealant

FP-5060

Pipe fitting

Pipe

Pipe fitting

Pipe

3. Surface

Mount

Instructions

1

Mounting surface

2

Remove sensor then use correct
screws for panel material.

Mounting surface (top),

68 mm (2.68 in.) bolt circle

120°

#6 or M3 metric

screws recommended

Mounting surface (side)

Sensor

Model

PULSES PER

U.S. GAL

PULSES PER

LITER

PULSES PER

mL

FP-5061

9950

2629

2.629

FP-5062

9950

2629

2.629

FP-5063

3160

834.9

0.835

FP-5064

3160

834.9

0.835