2.4.8 A/D Mode Control Register


(WRITE) Base+B : A/D Mode Control Register Format
Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

X SI2 SI1 SI0 X D2 D1 D0
X=don‘t care

Mode Select

Trigger Type

Transfer Type

D2 D1 D0 Software Trig

Pacer Trig

Software Interrupt

0 0 0

Select

X

Select

X

0 0 1

Select

X

Select

X

0 1 0

X

Select

X

X

1 1 0

X

Select

Select Select

X=disable

SI2 SI1 SI0 IRQ

Level

0 0 0 IRQ2
0 0 1 Not

used

0 1 0 IRQ2
0 1 1 IRQ3
1 0 0 IRQ4
1 0 1 IRQ5
1 1 0 IRQ6
1 1 1 IRQ7


The A/D conversion operation can be divided into 2 stages, trigger stage and transfer

stage. The trigger stage will generate a trigger signal to the A/D converter and the transfer
stage will transfer the results to the CPU.


The trigger method may be an internal trigger or an external trigger. The internal

trigger can be a software trigger or a pacer trigger. The software trigger is very simple
but can not control the sampling rate very precisely.
In software trigger mode, the
program issues a software trigger command (sec. 2.4.9) any time needed. Then the program
will poll the A/D status bit until the ready bit is 0 (sec. 2.4.2).

OME-A-8111 Hardware Manual (ver.1.1, Jul/2003) 16