Chapter 7 specifi cations, 1 specifi cations – Omega DPF500 Series User Manual

Page 16

Advertising
background image

12

Chapter 7 Specifi cations

ENVIRONMENTAL:

OPERATING TEMPERATURE

-4°F (-20°C) to + 158°F (70°C)

Extended Temp: -22°F (-30°C) to + 158°F (70°C)

HUMIDITY

0 - 90% Noncondensing

MOUNTING STYLES:

1- Panel Mount -

NEMA 4X Front

2- Wall Mount -

NEMA 4X Enclosure

(keypad mounted behind clear cover)

3- Explosion Proof -

Class I, Division I, Groups B, C & D

Class II, Division I, Groups E, F & G

INPUTS:

MAGNETIC PICKUP INPUT

Frequency Range: 0 to 3500 Hz

Trigger Sensitivity: 30 mV p-p (10 mV p-p on special order)

Over Voltage Protected: ± 30 VDC

OPTO-ISOLATED DC PULSE INPUT

High (logic 1): 4-30 VDC

Low (logic 0): Less Than 1 VDC

Minimum Current: .5 mA

Hysteresis: 0.4 VDC

Frequency Range: 0 to 5 kHz

Min. Pulse Width: 0.1 msec

CONTACT CLOSURE INPUT (contact closure to common)

Internal Pullup Resistor: 100 KΩ to +3.6 VDC

High (logic 1): Open or 4-30 VDC

Low (logic 0): Less Than .5 VDC

Internal Switch Debounce Filter: 0 to 40 Hz

NOTE: Sustained contact closure will shorten

battery life.

RESET INPUT (contact closure to common)

Internal Pullup Resistor: 100 KΩ to +3.6 VDC

High (logic 1): Open or 4-30 VDC

Low (logic 0): Less Than .5 VDC

Minimum On : 25 msec

NOTE: Sustained contact closure will shorten

battery life.

K-FACTOR

Range: 0.001 to 99999999

Decimal Point Locations: XXXX.XXXX to XXXXXXXX

20 POINT LINEARIZATION -LIN OPTION

This feature allows the user to enter 20 different frequencies

with 20 different corresponding K-Factors to linearize non linear

signals.

ANALOG OUTPUT -MA OPTION:

Type: 4-20 mA follows rate display, Two wire hookup

Accuracy: 0.025% Full Scale at 20° C

Temperature Drift: 50 ppm/°C Typical

Reverse Polarity Protected

Update Rate: 8 times/second

NOTE: The DPF500 uses the 4-20 mA loop power as its primary

power source when this option is used. The battery is still

required for standby battery operation.

DATA STORAGE:

Setup Information: Stored in fl ash memory

Totalizer: Stored in battery backed RAM but can be saved to

fl ash memory by operator for recall after battery change out.

7.1 Specifi cations

Power:

BATTERY POWERED

Supplied with 1 or 2 C size Lithium battery pack.

EXTERNAL POWER INPUT

Voltage: 8.5 to 30 VDC

Current: Less than 5 mA

Supplied with 1 C size lithium battery

Protection: Reverse Polarity Protection on DC Power Input

LOOP POWERED

Voltage: 8.5 to 30 VDC

Supplied with 1 or 2 C size lithium battery(ies)

Protection: Reverse Polarity Protection on Current Loop

Loop Burden: 8.5V maximum

BATTERY LIFE EXPECTANCY:

Expected Years of Operation for DPF500 of various powering op-

tions at equipment duty cycles

MODEL

RUN TIME

Idle

2hrs/day

8hrs/day 24hrs/day

-BAT*

10 yrs

10 yrs

10 yrs

9.1 yrs

-BAT-LIN

10 yrs

10 yrs

10 yrs

8.4 yrs

Standard unit 10 yrs

10 yrs

10 yrs

10 yrs

and -MA
(standby-operation)
Standard unit Indefi nite operation when externally powered
and -MA
External or loop power

* -BAT option contains DPF5-BP battery pack

NOTE: Battery shelf life is rated at 10 years by manufacturer

Life expectancy based on rated battery capacity at 20°C

The above table is shown with pulse output inactive. Use

of pulse output shortens battery life.

Example: A pulse output of 0.06 sec. duration, once per

second, would derate the battery life by 20%.

DISPLAY:

Rate Display: (selectable decimal)

5 Digits (99999), 0.35" High, Display updates once per second

with battery power, 8X per second with DC or Loop power

Rate Descriptors:

/SEC, /MIN, /HR

Min. Input Frequency: 0.01 Hz to 10 Hz (selectable delay of 0.1

to 99.9 seconds)*

Selectable Rate Display Damping

Totalizer Display: (selectable decimal)

8 Digits (99999999), 0.2" High

Totalizer Descriptors: GAL, LIT, FT3, M3, "blank"

Warning Displays: Low battery warning

PULSE OUTPUT:

The pulse output advances with the least signifi cant digit of the

totalizer or decimal multiples there of (see Pulse scale divider).

Type: Isolated photomos relay

Max. voltage (off state): 30 VDC

Current (on state): 100mA

Pulse Duration: Selectable 0.5, 0.25, 0.125, 0.0625 seconds

Pulse Scale divider (Pulscale): User selectable, ч1, ч10, ч100

or OFF

NOTE: Select OFF for max. battery life.

ACCURACY:

0.01% Reading, ±1 count

Temperature Drift: 50 ppm/°C Worst Case

* A large delay setting and internal math operations may delay the update rate.

-BAT*

10 yrs

10 yrs

10 yrs

9.1 yrs

Advertising