Mag input / dpf5-bp powered, Mag input / dc powered – Omega DPF500 Series User Manual

Page 8

Advertising
background image

4

Several typical applications of the DPF500 are shown below. Please observe that the various pulse inputs and power

options may be intermixed in many ways to solve common applications. The isolated pulse output may be freely

used so long as proper polarity is observed.

Caution: When 4-20 mA loop option is provided, the power wiring to the loop power option should always be to

terminals (+) 12 and (-) 11. Accidental wiring to (+) 12 and (-)6 should be avoided since excessive current

fl ow may result.

Caution: The magnetic pickup input and contact closure input require isolated sensors for proper operation. Ac-

cidental connections to earth may result in erroneous operation of the analog output and/or excessive

current fl ow.

Caution: Accidental connections from circuit common (3 or 6) to earth or terminal (11) may result in erroneous op-

eration of the analog output and/or excessive current fl ow.

2.4 Wiring

2.5 Typical Applications / Wiring Diagrams

+

+

-

1 Mag Input 1

2 Mag Input 2

3 Shield/GND

4 Reset Input

5 Contact Input

6 Common/ DC In (-)

6

5

4

3

2

1

-

To Shield

Pin 3

Flowmeter

with DC Pulse Output

+

-

Strip Chart

Recorder

24 VDC

Power

Supply

+

-

ISOLATED INPUT / 4-20mA LOOP POWERED

NOTE: Separate power supplies

are recommended to isolate output

from input.

If isolation is not a concern, use a

single power supply

4-20mA (+)/DC In (+) 12

4-20mA (-) 11

Opto Input (+) 10

Opto Input (-) 9

Opto Out (+) 8

Opto Out (-) 7

7

8

9

10

11

12

24 VDC

Power

Supply

PSU-24B

PSU-24B

Remote

Reset Switch

1 Mag Input 1

2 Mag Input 2

3 Shield/GND

4 Reset Input

5 Contact Input

6 Common/ DC In (-)

Turbine Meter with

Mag Pickup

6

5

4

3

2

1

MAG INPUT / DPF5-BP POWERED

4-20mA (+)/DC In (+) 12

4-20mA (-) 11

Opto Input (+) 10

Opto Input (-) 9

Opto Out (+) 8

Opto Out (-) 7

7

8

9

10

11

12

DPF5-BP PLUG-IN

CONNECTOR

DPF5-BP

Remote

Reset Switch

15 VDC

Power

Supply

+

-

1 Mag Input 1

2 Mag Input 2

3 Shield/GND

4 Reset Input

5 Contact Input

6 Common/ DC In (-)

Turbine Meter with

Mag Pickup

6

5

4

3

2

1

MAG INPUT / DC POWERED

4-20mA (+)/DC In (+) 12

4-20mA (-) 11

Opto Input (+) 10

Opto Input (-) 9

Opto Out (+) 8

Opto Out (-) 7

7

8

9

10

11

12

FPW-15

Flowmeter with

Switch Closure Output

4-20mA (+)/DC In (+) 12

4-20mA (-) 11

Opto Input (+) 10

Opto Input (-) 9

Opto Out (+) 8

Opto Out (-) 7

1 Mag Input 1

2 Mag Input 2

3 Shield/GND

4 Reset Input

5 Contact Input

6 Common/ DC In (-)

6

5

4

3

2

1

CONTACT INPUT / PULSE OUTPUT / BATTERY POWERED

DPF76 Totalizer

123456

4 1

7

8

9

10

11

12

Advertising