Oki MSM80C154S User Manual

Page 13

Advertising
background image

271

MSM80C154S/83C154S

¡ Semiconductor

External interrupt 0 signal is used in level-detect mode when this bit is "0" and in
trigger detect mode when "1".

NAME

ADDRESS

MSB

LSB

7

6

5

4

3

2

1

0

BIT LOCATION

FLAG

FUNCTION

TCON

88H

TF1

TR1

TF0

TR0

IE1

IT1

IE0

IT0

TCON.0

IT0

Interrupt request flag for external interrupt 0.
The bit is reset automatically when an interrupt is serviced.
The bit can be set and reset by software when IT0 = "1".

TCON.1

IE0

External interrupt 1 signal is used in level detect mode when this bit is "0", and in
trigger detect mode when "1".

TCON.2

IT1

Interrupt request flag for external interrupt 1.
The bit is reset automatically when an interrupt is serviced.
The bit can be set and reset by software when IT1 = "1".

TCON.3

IE1

Counting start and stop control bit for timer/counter 0.
Timer/counter 0 starts counting when this bit is "1", and stops counitng when "0".

TCON.4

TR0

Interrupt request flag for timer interrupt 0.
The bit is reset automatically when an interrupt is serviced.
The bit is set to "1" when a carry signal is generated from timer/counter 0.

TCON.5

TF0

Counting start and stop control bit for timer/counter 1.
The timer/counter 1 starts counting when this bit is "1", and stops counting when "0".

TCON.6

TR1

Interrupt request flag for timer interrupt 1.
The bit is reset automatically when interrupt is serviced.
The bit is set to "1" when carry signal is generated from timer/counter 1.

TCON.7

TF1

Timer control register (TCON)