Oki MSM80C154S User Manual

Page 29

Advertising
background image

287

MSM80C154S/83C154S

¡ Semiconductor

AC Characteristics

(1) External program memory access AC characteristics

Parameter

Symble

Unit

Min.

Max.

1 to 24 MHz

Variable clock from

41.7

1000

ns

t

CLCL

XTAL1, XTAL 2 Oscillation Cycle

2t

CLCL

-40

ns

t

LHLL

ALE Signal Width

1t

CLCL

-15

ns

t

AVLL

Address Setup Time

(to ALE Falling Edge)

1t

CLCL

-35

ns

t

LLAX

Address Hold Time

(from ALE Falling Edge)

4t

CLCL

-100

ns

t

LLPL

Instruction Data Read Time

(from ALE Falling Edge)

1t

CLCL

-30

ns

t

LLPL

From ALE Falling Edge to

PSEN

Falling Edge

3t

CLCL

-35

ns

t

PLPH

PSEN Signal Width

3t

CLCL

-45

ns

t

PLIV

Instruction Data Read Time

(from

PSEN Falling Edge)

0

ns

t

PXIX

Instruction Data Hold Time

(from

PSEN Rising Edge)

1t

CLCL

-20

ns

t

PXIZ

Bus Floating Time after Instruction

Data Read (from

PSEN Rising Edge)

5t

CLCL

-105

ns

t

AVIV

Instruction Data Read Time

(from Address Output)

0

ns

t

AZPL

Bus Floating Time(

PSEN Rising

Edge from Address float)

1t

CLCL

-20

ns

t

PXAV

Address Output Time from

PSEN

Rising Edge

*1

V

CC

=2.2 to 6.0V, V

SS

=0V, Ta=–40°C to +85°C

PORT 0, ALE, and

PSEN connected with 100pF load, other connected with 80pF load

*1 The variable check is from 0 to 24 MHz when the external check is used.

Advertising