WiSER 2400 Technical Manual

Version 2.16

Copyright  2001-2005, OTC Wireless, Inc. All Rights Reserved

Page 16 of 32

2.2.2 Using the WiSER2400 in a point-to-multiple

point link

Scheme 4

See Figure 8 (overleaf)

Configure each WiSER2400 on the device side to match its serial
parameters (baud rate, parity bit, … etc.) with that of the serial
device it is to be attached to. Configuration can be done by
temporarily connecting the WiSER2400, by a serial cable or
wirelessly, to a PC running the WiSER2400 administration software.

Similarly, configure the serial parameters of the WiSER2400 on the
PC side so that it can communicate with the PC.

Configure the WiSER2400s on either side of the link to match up
their UDP/IP settings (listening port, destination IP address, … etc.)
for a UDP/IP connection. Enable the WiSER2400 on the PC side to
send UDP broadcasts. Enable each WiSER2400 on the device side
to receive UDP broadcasts.

Configure the WiSER2400s on both sides to operate in the Ad-hoc
mode.

Attach the WiSER2400s to the serial device and the PC.

Establish the wireless link between the PC and the WiSER2400.

The system is now ready for running the application software on the
PC to control the serial devices through the wireless link.

Please refer to Section 3 of this manual for details on configuring the
WiSER2400.