Installation - electronic (pulse output only) – Omega Engineering FPR 200 User Manual

Page 7

Advertising
background image

Installation - Electronic (Pulse Output Only)

The flow sensor pulse output circuit is a three-wire DC-powered design

that transmits a frequency proportional to flow rate. The circuit operates on

5-24 V

DC

and will consume a maximum of 25 mA from the power supply.

1. Connect the red wire (pin 1 for units with the electronic disconnect

option) from the sensor to the positive terminal of the 5-24VDC

power supply.

2. Connect the black wire from the transmitter (pin 2 for units with the

electronic disconnect option) to the negative terminal of the 5-24

V

DC

power supply.

3. Connect the green wire from the transmitter (pin 3 for units with

electronic disconnect) to the (+) pulse input of the data acquisition

device. This connection may be labeled "Pulse In" or "DC Input"

on some devices.

4. If applicable, connect the negative side of the power supply to the

negative side of the pulse input.

5. Apply power to the system.

6. If everything is operating correctly, the data acquisition device should

begin "counting" pulses when fluid starts flowing through the sensor.

If the data acquisition device is not “counting”:

„ check wiring terminations for good connections

„ verify correct supply voltage and current

7. The installation should be complete. The relationship between the

frequency output and flow rate is shown in the graphs above.

(7)

Flow Rate vs. Frequency Output

Standard 1/2" NPTF Units

0

10

20

30

40

50

60

0

2

4

6

8

10

12

14

16

Flow Rate (GPM)

Frequency (Hz)

Flow Rate vs. Frequency Output

Standard 3/4" & 1" NPTF Units

0

10

20

30

40

50

60

0

10

20

30

40

50

60

Flow Rate (GPM)

Frequency (Hz)