A826u.pas, 3 a826u.pas – Omega Engineering OME-A826PG User Manual

Page 31

Advertising
background image

OME-A-826PG Software Manual [Win 95/98/NT]

2.3.3 A826U.PAS


unit A826U;

interface

type PSingle=^Single;
type PWord=^Word;
type PInteger=^Integer;
type PSmallInt=^PSmallInt;

Function A826_AD2F(hex, Gain :Word): Single ; StdCall;

implementation

uses math;


//*-----------------------------------------------------*
//* Return voltage value or -100.0 if any error occurs *
//* or parameter is out of range. *
//*

Gain

:

0-3

*

//*-----------------------------------------------------*
Function A826_AD2F(hex, Gain :Word): Single ;
Var
ZeroBase, VoltageRange, FullRange : Single ;
i : Integer ;

Begin

ZeroBase := 0;
FullRange := 32767;
VoltageRange := 10;

i := hex;
if i > $7FFF then

i := ((Not hex) + 1) * -1 ;

Gain := Gain mod 16 ;

If (Gain < 0) Or (Gain > 3) Then
begin
result := -100;
exit;
end;

Result := ((((i - ZeroBase) / FullRange) * VoltageRange) / Power(2, Gain));

End;

end.

Date: Aug-15-2000 Ver: 2.2 Page 29