Range configuration code, 2 range configuration code – Omega Engineering OME-A826PG User Manual

Page 8

Advertising
background image

OME-A-826PG Software Manual [Win 95/98/NT]

1.2

Range Configuration Code

The AD converter of the OME-A-826PG is 16 bits under all

configuration code. If the analog input range is configured to

±5V range, the

resolution of one bit is equal to 2.44 mV. If the analog input range is configured to
±2.5V range, the resolution will be 1.22 mV. If the analog input signal is about
1 V, use configuration 0/1/2 (for OME-A-826PG), it will get nearly the same result
except resolution. So choose the correct configuration code can achieve
the most high precision measurement.


OME-A-826PG Input Signal Range Configuration Code Table

Bipolar/Unipolar

Input Signal Range

Configuration Code

Bipolar

± 10V

0

Bipolar

± 5V

1

Bipolar

± 2.5V

2

Bipolar

± 1.25V

3

Date: Aug-15-2000 Ver: 2.2 Page 6