Ad, interrupt functions, A826_installirq, A826_ad_int_start – Omega Engineering OME-A826PG User Manual

Page 46: 5 ad, interrupt functions, 1 a826_installirq 3.5.2 a826_ad_int_start, 1 a826_installirq, 2 a826_ad_int_start

Advertising
background image

OME-A-826PG Software Manual [Win 95/98/NT]

3.5

AD, Interrupt functions

3.5.1 A826_InstallIrq

z

Description:

This subroutine will install interrupt handler for a specific IRQ level n.

z

Syntax:

WORD A826_InstallIrq(WORD wBase, WORD wIrq,

HANDLE *hEvent, DWORD dwCount );

z

Parameter:

wBase :

[

Input

] The I/O port base address for A826 card.

wIrq

:

[

Input

] The IRQ level .

hEvent :

[

Input

] The handle of event object that created by user.

dwCount :

[

Input

] The desired A/D entries count for interrupt transfer.

z

Return Value:

NoError

: successful

InstallIrqError: fail in install IRQ handler.


3.5.2 A826_AD_INT_Start

z

Description:

This subroutine will start the interrupt transfer for a specific A/D channel

and programming the gain code and sampling rate..

z

Syntax:

WORD A826_AD_INT_Start(WORD Ch, WORD Gain, WORD c1, Word c2 )

z

Parameter:

Ch :

[

Input

] the A/D channel.

Gain :

[

Input

] the Gain

c1,c2

: [

Input

] the sampling rate is 2M/(c1*c2)

z

Return Value:

NoError

: successful

INTStartError :

fail

Date: Aug-15-2000 Ver: 2.2 Page 44