Cus listed, General description, Safety summary – Omega Vehicle Security LDP63100 User Manual

Page 3: Specifications, Dimensions in inches (mm)

Advertising
background image

3

z LARGE LED DISPLAY READABLE TO 180 FEET

z VARIOUS ANALOG INPUT MODULES;

DC VOLTAGE AND CURRENT
PROCESS SIGNALS
TRUE RMS VOLTAGE AND CURRENT
THERMOCOUPLE OR RTD
STRAIN GAGE/BRIDGE

z ALARMS, ANALOG OUTPUT, AND COMMUNICATION

z PROGRAMMABLE USER INPUTS

z UNIVERSAL AC POWERED (85 to 250 VAC)

z PROGRAMMING SOFTWARE

z NEMA 4X/IP65

GENERAL DESCRIPTION

The LDP63100 is a versatile display that can increase productivity by

offering the plant floor or production area a large visual display of their current
status. Whether your measurement is voltage, current, process, temperature, or
strain gage, the LDP63100 can satisfy your requirement. Plug-in option cards
can add alarms, analog output, and communication/bus capabilities, making the
LDP63100 a truly Intelligent Panel Meter.

SAFETY SUMMARY

All safety regulations, local codes and instructions that appear in this and

corresponding literature, or on equipment, must be observed to ensure personal
safety and to prevent damage to either the instrument or equipment connected
to it. If equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.

The protective conductor terminal is bonded to conductive

parts of the equipment for safety purposes and must be
connected to an external protective earthing system.

SPECIFICATIONS

Input specifications, wiring, and programming information is contained in
the corresponding literature shipped with the ordered model.

1. DISPLAY: 4" (101 mm) Red LED

5-Digit: -19999 to 99999

2. POWER REQUIREMENTS:

AC Input Modules: 85 to 250 VAC, 50/60 Hz, 18 VA
LDP63100 Display: 85 to 250 VAC, 50/60 Hz, 10 VA

3. ANNUNCIATORS:

Display Indication: Three vertical dots on the left side of the unit identify

the displays for the following modes:

Setpoint Indication: Four vertical dots on the right side of the unit identify

the setpoint “ON” condition, with SP 1 being the top position through SP
4 at the bottom.

4. LDP63100 Programming: The unit is a large display, designed to be

remotely mounted. Therefore, the unit does not have a programming keypad.
Unit programming should be accomplished by one of the following methods:
Rear Terminal Block: External switches can be wired via the terminal block

to allow unit programming. A minimum of 3 switches would be required.

Optional Programming Remote (LDP6-PGM): This option provides a 10

foot interconnecting cable and programming box. The Programming
Remote contains buttons allowing easy programming of the display.

Optional Serial Programming: You can purchase an RS232 or RS485 Comms

Card and program the unit via Crimson, a Windows

®

based software

program.

DIMENSIONS In inches (mm)

CAUTION: Risk of Danger

Read complete instructions prior to

installation and operation of the unit.

CAUTION:

Risk of electric shock.

TOP

Maximum

MIDDLE

Minimum

BOTTOM

Total

C

US LISTED

UL

R

IND. CONT. EQ.

51EB

Advertising