Command set:


Display parameters:

UNITS

OHMS

UNITS

C

UNITS

K

UNITS

F

INPUT

A

INPUT

B

INPUT

A-B


Analogue parameters:

SPAN

Value in Ohms

ZERO Value in Ohms


Measurement:

MEASURE


Return to Local:

LOCAL


Output Protocol

Replies will depend on the command implemented, and will be numeric or – with
commas and spaces as delimiters. All replies will be terminated by CR and LF. The
first number will be an error code.

0

No error

1

Calibration lost (EEPROM corruption)

2

3

Broken probe

4

Syntax error

6
7


There will be no fur ther numbers if:

a)

There is an error

b)

The primary command was UNITS, INPUT or LOCAL


Further output will be provided in the case of MEASURE, DUMP (DIAGNOSE).

1.

MEASURE
Eg. If output is 0, 2351.7


First number

- error code

Second number

- value in units set by previous commands