4. Calibration


The OME-A-822PGL/PGH is factory calibrated for optimum performance. Recalibration is
suggested for high vibration environments. The following items are required for
calibrating the OME-A-822PGL/PGH.

z

One 6 digit multimeter

z

One stable voltage source (4.9988V)

z

Diagnostic program : this program included with the

OME-A822PGL/PGH.


4.1 Description of Variable Resistors


There are seven variable resistors(VRs) on the OME-A-822PGL/PGH used for calibration,
they are described below.

VR Num. Description
VR1

A/D offset adjustment

VR2

A/D gain adjustment

VR3

D/A channel 0 gain adjustment

VR4

D/A channel 1 gain adjustment

VR5

D/A reference voltage adjustment

VR6

A/D unipolar offset adjustment

VR7

A/D programmable amplifier offset adjustment

OME-A-822PGL/PGH Hardware Manual ---- 41