Omron E7 User Manual

Page 9

Advertising
background image

G7/F7/L7/E7 inverter PLC

373

F7 + PLC

The F7 drive is a flux vector control inverter. It is intended to handle every conventional drive application found in a typical industrial manufacturing
plant from simple variable torque pumping to sophisticated networked material handling. By combining with PLC option board, is ideal solution
winding/unwiding applications, handling/ transfer/ palletizer point-to-point positioning applications, food processing, packaging, printing, and textile
machines for example .

Note:

For detailed information about the inverter, please see into the Varispeed F7 series section.

E7 + PLC

Varispeed E7 is the OMRON Yaskawa solution for energy saving applications The E7 is designed for variable torque applications such as fans
and centrifugal pumps. By combining with PLC option board, it is the ideal solution for water treatment, pump squencing, building automation and
fan applications for example...

Note:

For detailed information about the inverter, please see into the Varispeed E7 series section.

F7 + PLC in a winding application example.

E7 + PCL in HVAC application example

M

Encoder

PG

HMI interface

M

M

M

F7 + PLC

Load cell

F7

F7

F7

Water

Air

Air

Air

Air

Compobus/S

up to 16 / 32 slaves

Analogue inputs

Digital
outputs

Digital
inputs

HMI interface

Scada

building controller

E7 + PLC

Temperature

sensors

Cooling tower

Y203-EN2-02-Katalog.book Seite 373 Mittwoch, 24. Mai 2006 2:22 14

Advertising
This manual is related to the following products:

G7, F7, L7