4 − us-1800 control panel settings, Overview, Control panel settings – Tascam US-1800 User Manual

Page 12: Audio performance, Sample clock source, Digital output format, Digital output chanels, Overview control panel settings

Advertising
background image

12

TASCAM US-1800

4 − US-1800 Control panel settings

Overview

The Control Panel lets you make various settings for the

US-1800’s functionality.
On Windows OS, the US-1800 Control Panel shortcut can

be found in the Windows Start menu > Control Panel or

the Start menu > All Programs > TASCAM. On Mac OS X, the
US-1800 Control Panel is located in the Applications folder.

Other useful audio and MIDI settings for Mac OS X can be

found in Applications/Utilities/Audio MIDI Setup.

[Windows Control Panel]

[Mac OS X Control Panel]

Control panel settings

Audio Performance

The US-1800 driver temporarily stores input and output

audio sample in buffers. The size of these buffers can

be adjusted. A smaller buffer size will reduce the delay

when monitoring the audio signal, but will require

your computer to perform the processing faster. If the

processing does not occur in time (e.g., if other system

operations are occurring), you may hear clicks, pops, or

dropouts in the audio signal. A larger buffer size provides

more safety against such problems caused by other

system activities, but will produce greater delay when

monitoring the audio signal. You should select the buffer

size that works best for your system.
On the Windows version of the US-1800 Control Panel,

the Audio Performance setting permits you to adjust the

buffer size that will be used by all audio applications. The
lowest latency setting is the minimum buffer size, and the
highest latency setting is the maximum buffer size.

On Mac OS X, the buffer size is determined by each

audio application. Consequently, there is no “Audio

Performance” setting on the Mac OS X version of the

US-1800 Control Panel. Some applications select the

buffer size automatically while others permit the user

to select the buffer size. Please consult your audio

application’s documentation for details.

Sample Clock Source

The clock source can be set to Automatic or Internal. When

using digital input, set this to Automatic.

Automatic

(default): If a clock signal is input through

the

DIGITAL IN

jack, it is used. If no signal is input

through the

DIGITAL IN

jack, this unit’s internal clock is

used.
Internal

: This unit’s internal clock is always used.

Digital Output Format

Set the digital output format to AES/EBU or S/PDIF.

Digital Output Channels

The

DIGITAL OUT

jack outputs either digital signals of

LINE

OUTPUTS 1/2

or

3/4

. You select which pair of signals to

output using this item.

CAUTION

When using the digital input (

DIGITAL IN

), set Sample

Clock Source to automatic, and set the connected device

as the clock master. Devices that cannot function as a

clock master cannot be used with this unit. When the

digital input (

DIGITAL IN

) and digital output (

DIGITAL OUT

)

are used at the same time, if the Control Panel Sample
Clock Source is set to internal, the DIGITAL IN signal cannot

be received, so the DIGITAL OUT sound is returned to the

DIGITAL IN as is, resulting in a feedback loop.