15

Figure 7 - Audiocom Intercom Cables

Pair 1

Pair 1

Pair 1

Pair 2

Pair 2

Pair 2

Pair 3

Pair 3

TYPICAL 2-CHANNEL CABLE WIRING

“Y” CABLE WIRING

TYPICAL 1-CHANNEL CABLE WIRING

Cable Type: 22AWG Stranded, 3-Pair Twisted-wire, with Shield

Pin 3: Channel 1 Audio / Power
Pin 4: Channel 1 Audio / Power
Pin 5: Channel 2 Audio / Power
Pin 6: Channel 2 Audio / Power

: Earth ground

Connector Type: 6-Pin XLR Audio (Neutrik only, not compatible with 6-pin Switchcraft)
Pin 1: Channel 1 & 2 Common
Pin 2: No connection

*

Shield

Cable Type: 22AWG Stranded, 2-Pair Twisted-wire, with Shield

Channel Audio / Power

Pin 3: Channel Audio / Power

: Earth ground

Connector Type: 3-Pin XLR Audio (Neutrik or Switchcraft)
Pin 1: Common
Pin 2:

*

Shield

*

Standard cables are generally constructed using a male connector at one end and a
female connector at the other end. This allows several cables to be interconnected to
create longer cable runs.

Audiocom power supplies use a 3-pin male Neutrik connector for

each channel. Audiocom wallplates use male Neutrik connectors.

Audiocom master stations, speaker stations and belt packs

also typically provide both a male and female Neutrik connector for each intercom
channel. This permits loop-through connection of several intercom stations using the
standard cables.

Use second drain wire if available, or add an extra section of wire.

Ch1

Ch2

Denotes twisted pair.

Denotes twisted pair.

Denotes shield.

Denotes shield.

3

3

3

3

2

2

2

2

1

1

1

Shield

Shield

Case

Shield

4

4

4

3

3

3

6

6

6

5

5

5

1

1 (Both wires)

1 (Both wires)

1 (Both wires)

Shield

Shield

Shield