5 register control, 6 miscellaneous settings, 3 basic test procedure – Texas Instruments DAC3482 User Manual

Page 8: 1 test block diagram, Pc +5v +6 v, Tsw3100 pattern generator, 3basic test procedure

Advertising
background image

PC

+5V

+6 V

Ethernet

USB

J13

J9

DAC348X

J14

J18

TSW3100

Pattern

Generator

J74

J13

C

ro

s

s

-o

v

e

r

E

th

e

rn

e

t

C

a

b

le

U

S

B

M

in

i-

B

C

a

b

le

RF

LO

Spectrum

Analyzer

Signal

Generator

(LO Source)

Signal

Generator

(CLK Source)

J9

Basic Test Procedure

www.ti.com

2.2.5

Register Control

Send All: Sends the register configuration to all devices

Read All: Reads register configuration from DAC348x device

Load Regs: Load a register file for all devices. Sample configuration files for common frequency
plans are located in the install directory.

O Select Load Regs button.

O Double click on the data folder.

O Double click on the desired register file.

O Click on Send All to ensure all of the values are loaded properly.

Save Regs: Saves the register configuration for all devices

2.2.6

Miscellaneous Settings

Reset USB: Toggle this button if the USB port is not responding. This generates a new USB handle
address

O Note: It is recommended that the board be reset after every power cycle and the “reset usb”

button on the GUI be clicked.

Exit: Stops the program

3

Basic Test Procedure

This section outlines the basic test procedure for testing the EVM.

3.1

Test Block Diagram

The test set-up for general testing of the DAC348x with the TSW3100 pattern generation card is shown in

Figure 7

.

Figure 7. Test Set-up Block Diagram

8

DAC3484/DAC3482 EVM

SLAU336 – March 2011

Submit Documentation Feedback

© 2011, Texas Instruments Incorporated

Advertising