Instructions for the Installer

Engineers technical data

Important safety requirements

This hob must be installed in accordance with the IEE

Wiring Regulations (Current Edition).

Detailed recommendations are contained in the following

British Standards Codes Of Practice: B.S. 6172/ B.S.

5440, Par. 2 and B.S. 6891 Current Editions.

Location

This hob has been registered as a "Class X" appliance

according to Fire Risk Regulations. Minimum distances

detailed below must be observed. The hob may be located

in a kitchen, a kitchen/diner or bed sitting room, but not

in a bathroom or shower room.

Before making the cut out in the worktop ensure that

there is a minimum distance of 55 mm. between the rear

edge of the hob and the wall. A minimum distance of 100

mm. must be left between the side edges of the hob and

any adjacent cabinets or walls.

The minimum distance combustible material can be fitted

above the hob in line with the edges of the hob is 400

mm. If it is fitted below 400 mm. a space of 50 mm. must

be allowed from the edges of the hob.

The minimum distance combustible material can be fitted

directly above the hob is 700 mm.

650 mm

400 mm

400 mm

100 mm

50 mm

50 mm

55 mm

600 mm

INSTALLATION GUIDANCE INSTRUCTIONS

CLEARANCES REQUIRED

WHEN FITTING THE HOB

WITH A COOKER HOOD ABOVE

FO 0813

700 mm

400 mm

100 mm

400 mm

50 mm

55 mm

50 mm

INSTALLATION GUIDANCE INSTRUCTIONS

CLEARANCES REQUIRED

WHEN FITTING THE HOB

WITHOUT A COOKER HOOD ABOVE

FO 0812

Heating elements Ratings

Normal front left Hotplate

Ø 180 mm

1570 W

Normal back left Hotplate

Ø 145 mm

1040 W

Rapid front right Hotplate

Ø 145 mm

1570 W

Rapid back right Hotplate

Ø 180 mm

2090 W

Total rating

6270 W

Cut out dimensions

Width:

550 mm.

Depth:

470 mm.

Overall dimensions

Width:

580 mm.

Depth:

500 mm.