Building in, Installation, Building over a cupboard or drawer – Tricity Bendix TBE 635 User Manual

Page 11: Supply connections, Cut out size

Advertising
background image

11

Building In

ON/OFF SWITCH

FLEX
OUTLET

ON/OFF SWITCH

FLEX
OUTLET

FO 0763

FO 0764

1

2

Building over a cupboard or

drawer

If the hob is to be installed above a cupboard or drawer it

will be necessary to fit a heat resistant board below the

base of the hob on the underside of the work surface.

It is also recommended to carry out the electrical

connection to the hob as shown in diagrams 1 and 2.

Rectangular cut-out size for hob

Installation

The hob must be installed according to the

instructions supplied.

The hob must be installed by qualified personnel

to the relevant British Standards.
Please, ensure that, once the hob is installed, it

is easily accessible for the engineer in the event

of a breakdown.

Supply connections

This hob is designed to be connected to 230-240 V

(50Hz) electricity supply.
The hob has a terminal block which is marked as follows:
L

- Live terminal

N

- Neutral terminal

or E

- Earth terminal

The cable used to connect the hob to the electrical supply

must be 6mm, PVC twin and earth, and fused to 30amp.
It is necessary that you install a double pole switch

between the hob and the electricity supply (mains), with

a minimum gap of 3mm between the switch contacts

and of a type suitable for the required load in compliance

with the current rules.

The switch must not break the yellow and green earth

cable at any point.

550

470

55 min.

30

FO 2098

WHEN THE HOB IS FIRST INSTALLED

Once the hob has been installed, it is important

to remove any protective materials, which were

put on in the factory.

The manufacturer will not accept liability, should

the above instructions or any of the other safety

instructions incorporated in this book be ignored.

Cut Out Size

The dimensions of the cut-out are given in the diagram.

Advertising