Electrical connections, Supply cable specifications – Tricity Bendix TBE 635 User Manual

Page 13

Advertising
background image

13

Electrical connections

Any electrical work required to install this hob

should be carried out by a qualified electrician or

competent person, in accordance with the current

regulations.

THIS HOB MUST BE EARTHED.

The manufacturer declines any liability should these

safety measures not be observed.

This hob is designed to be connected to a 230-240V 50Hz

AC electrical supply.

Before switching on, make sure the electricity supply

voltage is the same as that indicated on the hob rating

plate. The rating plate is located on the bottom of the

hob. A copy is attached on the back cover of this book.

The hob is supplied without supply cord. A 3 core flexible

supply cord must be fitted, in accordance with the

specification given in the relevant tables.

1) Remove the mains terminal cover plate from

the underside of the hob, to expose the mains

terminal block.

2) Loosen the two cable clamp screws and lift

the top section of the clamp enough to allow

the cable to be passed through.

3) Connect the red (live) wire to the terminal which

is marked with the letter "L".

4) Connect the black (neutral) wire to the terminal

which is marked with the letter "N".

5) After fitting a green or yellow/green sleeve over

the bare copper wire (earth wire), connect the

exposed end to the terminal which is marked
with the earth symbol

or with the letter

"E"coloured green and yellow.

NOTE:

The earth wire should be about 2 cm. longer

than the live and neutral wires.

6) Secure the cable by means of the clamp

screws and refit the terminal block cover.

The hob should be connected to a double pole switch

with a minimum gap of 3 mm. between the switch

contacts and of a type suitable for the required load in

compliance with the current electric regulations. The

switch should be sited within 2m of the hob and be easily

accessible upon completion of the installation.

The switch must not break the yellow and green earth

cable at any point.

Ensure that the hob supply cord does not come

into contact with surfaces with temperatures

higher than 50 deg. C.

L

N

FO 0306

Supply Cable Specifications

Connection

Min. size

Cable / flex Fuse

via

Cable/flex type

• Cooker

6 mm

2

PVC/PVC

30 A

Control

twin and

Circuit

earth

For Uk use only

For Europe use only

Min. size Cable/flex Cable / flex type

Fuse

2.5 mm

2

H05 RR-F / H05V2V2 20 A

H05 BB-F

F

Advertising