background image

Appendix I: Log and SNMP Trap Numbers

Datacryptor Ethernet User Manual

Page 106

THALES

Log Trap Errors Hardware

Log Type

Code

Trap
No.

Severity Message

Information

Error
(Hardware)

1

120

Critical

Random no. generator fault

Error
(Hardware)

2

120

Critical

Real time clock faulty

Error
(Hardware)

3 120

Critical RAM

faulty

Error
(Hardware)

4

120

Critical

Encrypt Clock Limit
Exceeded

Line clock is too fast for
the unit

Error
(Hardware)

5

120

Critical

Decrypt Clock Limit
Exceeded

Line clock is too fast for
the unit

Error
(Hardware)

6

120

Critical

Encrypt Clock Stopped

Error
(Hardware)

7 120

Critical Decrypt Clock Stopped

Error
(Hardware)

8 120

Critical Battery

may need replacing

Battery may be more than
10 years old or exhibiting
symptoms of low voltage

Error
(Hardware)

9

120

Critical

Random Number Generator
diagnostics Failed

Error
(Hardware)

10 120

Critical

Continuous

Random

Number

Generator test failed

Error
(Hardware)

11

120

Critical

Real Time Clock not set: set
or check battery

Error
(Hardware)

12 120

Critical

Hardware

Monitor

reports

alarm

This can be due to fan,
heat or power failure.
Note that power failure is
reported separately.

Error
(Hardware)

13 120

Critical

Power

Monitor reports alarm