Appendix I: Log and SNMP Trap Numbers

Datacryptor Ethernet User Manual

Page 126

THALES

Log Type

Code

Trap
No.

Severity Message

Information

Audit

75

762

Critical

Primary mode reboot: KAT
test failure

The encryption algorithm
failed a "Known Answer
Test" (KAT) and has
caused the unit to reboot
to attempt to recover.

Audit

76

763

Critical

Secondary mode reboot: KAT
test failure

The encryption algorithm
failed a "Known Answer
Test" (KAT) and has
caused the unit to reboot
to attempt to recover.

Audit

77

764

Major

Hot Standby reboot: FPGA
stats mismatch

Hot standby unit has
detected a possible
problem with the
encryption device and has
caused the unit to reboot
to attempt to recover.

Audit

78

765

Major

Hot Standby reboot: No
response from Private CR

Hot standby unit may
have detected problem
with Host (Private) port
Ethernet interface which
appears to have stopped
responding and has
caused the unit to reboot
to attempt to recover

Audit

79

766

Major

Hot Standby reboot: No
response from Public CR

Hot standby unit may
have detected problem
with Network (Public) port
Ethernet interface which
appears to have stopped
responding and has
caused the unit to reboot
to attempt to recover

Audit

80

767

Major

Hot Standby reboot: Failed to
change IP address

Hot Standby unit:
changing of an IP address
appears to have failed and
has caused the unit to
reboot to attempt to
recover

Audit

81

768

Major

Detected Primary failure: No
response from Public virtual
IP address

Secondary unit has
detected Primary unit
failure on Network (public)
port side

Audit

82

769

Major

Detected primary failure: No
response from Private virtual
IP address

Secondary unit has
detected Primary unit
failure on Host (private)
port side

Audit

83

770

Major

Primary: Response back from
Public virtual IP address

Hot standby: primary unit
has detected itself,
probable configuration
error on public side