TOA Electronics THS4130 User Manual

Page 18

Advertising
background image

2-2

Using the THS4130 EVM

2.1

Required Equipment

-

One double-output dc power supply (

±

5 V, 100 mA output minimum)

-

Two dc current meters with resolution to 1 mA and capable of the
maximum current the dc power supply can supply. If available, set the
current limit on the dc power supply to 100 mA.

Note: Some power supplies incorporate current meters which may be
applicable to this test.

-

50-

source impedance function generator (1 MHz, 10 V

PP

sine wave)

-

Oscilloscope (50-MHz bandwidth minimum, 50-

input impedance).

2.2

Power Supply Setup

1) Set the dc power supply to

±

5 V.

2) Make sure the dc power supply is turned off before proceeding to the next

step.

3) Connect the positive (+) terminal of the power supply to the positive (+)

terminal of the current meter number 1.

4) Connect the negative (–) terminal of the current meter number 1 to the

V

CC+

of the EVM (J7).

5) Connect the common ground terminal of the power supply to the ground

GND on the EVM (J9).

6) Connect the negative (–) terminal of the power supply to the negative (–)

terminal of the second current meter.

7) Connect the positive (+) terminal of the current meter number 2 to the V

CC–

of the EVM (J8).

Figure 2–1. Power Supply Connection

POWER SUPPLY

GND

–5V

+5V

+

+

CURRENT

METER 2

CURRENT

METER 1

J8 V

CC–

J9 GND

J7 V

CC+

J6 V

OCM

EVM

THS4130

Figures are not drawn to scale.