3 input and output setup – TOA Electronics THS4130 User Manual

Page 19

Advertising
background image

2-3

Using the THS4130 EVM

2.3

Input and Output Setup

1) Ensure that JU3, JU4, and JU1 are

not installed (open circuit).

2) Set the function generator to generate a 1 MHz,

±

0.5 V (1 V

PP

) sine wave

with no dc offset.

3) Turn off the function generator before proceeding to the next step.

4) Using a BNC-to-SMA cable, connect the function generator to J1 (V

I+

) on

the EVM.

5) Using a BNC-to-SMA cable, connect the oscilloscope to J3 (V

O–

) on the

EVM.

6) Using a BNC-to-SMA cable, connect the oscilloscope to J4 (V

O+

) on the

EVM. Set the oscilloscope to 0.5 V/division and a time-base of 0.2

µ

s/division.

Note: The oscilloscope must be set to use a 50-

input impedance for

proper results.

Figure 2–2. Signal Connections

OUT

1 MHz
1 V

PP

0 V Offset

50

Source

Impedance

J1 V

in+

J3 V

out–

J4 V

out+

CH-1

CH-2

THS4130 EVM

FUNCTION

GENERATOR

OSCILLOSCOPE

50

Impedance

Figures are not drawn to scale.