TOA Electronics THS4130 User Manual

Page 20

Advertising
background image

2-4

Using the THS4130 EVM

2.4

Testing the EVM Setup

1) Turn on the dc power supply.

2) Verify that both the +5 V (current meter 1) and the –5 V (current meter 2)

currents are below 20 mA.

Caution:

Currents above 20 mA indicate a possible short or a wrong resistor value
on the PCB. Do not proceed until this situation is corrected.

3) Turn on the function generator.

4) Verify the oscilloscope is showing two 1 MHz sine waves with amplitude

of

±

0.125 V. The dc offset of the signal must be below 50 mV.

Note: V

OUT+

and V

OUT–

should be 180 degrees out of phase. The internal

attenuation of the scope should be set to 6 dB for a gain of one. Otherwise,
the output will show a

gain of one-half due to the voltage division occurring

at the 50-

termination resistor.

Use Figure 3 as a reference for the input and output signals.

Figure 2–3. Driver 1 Output Signal

THS4130

C3

C2

C1