Thermo Products USDT2004 User Manual

Page 11

Advertising
background image

11

START

Starts pump at pre-set insolation (solar radiation intensity)

ALARM

Enables/Disables protection functions

BTU

Energy calculation and setting


ensor Designation – USDT 2004 accepts two different sensor types or a reference
value . User can program a constant reference temperature instead of a sensor output.
The factory-preset sensor is the thermistor (KTY 10) type. The KTY 10 tank sensor,

white wire, should be used in a conditioned environment and will not be permanently damaged up
to 360

o

F.


Selection:

S1

Sensor 1 (collector outlet) selection

S2

Sensor 2 (collector inlet) selection

S3

Sensor 3 (tank) selection


Designation:

PT

PT 1000 sensor (1000 O at 0

o

C, not available in US market)

KTY

Thermistor sensor (2000 O at 25

o

C)

250

250

o

F reference temperature

- 4

- 4

o

F reference temperature

Sensor wires can receive electromagnetic pulses, which can result in a wrong temperature
reading. The USDT 2004 reads sensor values every 50 ms. It can bundle several readings and
process their average.

AV 1 Sensor 1 average
AV 2

Sensor 2 average

AV 3 Sensor 3 average

The numbers of samples can be programmed from 4 to 20. The impedance characteristics of
sensors temperature dependencies are represented in the following table:

T

0

10

20

25

30

40

50

60

70

80

90

100°C

R(KTY)

1630

1772

1922

2000

2080

2245

2417

2597

2785

2980

3182

3392




rost
and overheating protections - Pump operation can be manipulated by the user in
both collector stagnation and frost conditions. The set-up is possible in System Guard,

SGUARD, domain.

Overheating protection – The Circulation pump may not be powerful enough to circulate the
heat transfer fluid in the solar loop with air pockets. User can program the pump to stop at a
desired maximum collector temperature, shown by

? symbol, to protect the pump. The USDT

2004 will take over the normal operation after the temperature decreases to an acceptable
working temperature, shown as

=. This feature is disabled at 299

o

F set point.

Frost Protection – Frost protection in the sun-belt region is provided by circulating water in the
solar loop when freezing conditions exist. Regardless of the temperature difference ? T, the

S

F