11.2 RING CADENCE CONFIGURATION

Using the above notation, the BNF description for the ring cadence patterns is as follows:

Timeval ::= time in milliseconds

Repeatval ::= # of cycles to repeat

Tonename ::= "RING_0" | "RING_1" | "RING_2" | "RING_3" |

"RING_4"| "RING_5" | "RING_6" | "RING_7" | "RING_8" |

"RING_9"

Idle ::= "IDLE"

Active ::= "ON" | "OFF"

Inactive ::= Idle "(" Timeval ")"

Active ::= Active "(" Timeval ")"

Sequence ::= Active | Active "," Sequence

Repetition ::= "[" Sequence "]" Repeatval

Repeat ::= "R"

Cycle ::= Sequence | Repetition

Fullsequence ::= Cycle | Cycle "," Fullsequence

Cadence ::= Fullsequence | Fullsequence "," Repeat |

Fullsequence"," Inactive "," Repeat

Ring ::= Cadence

EXAMPLE RING CADENCE CONFIGURATION

For the ring cadence pattern above, the configuration would be:

RING_0 ON(200),OFF(300),ON(100),OFF(400),ON(200),OFF(4000),R

The Bellcore standard ring cadence patterns are:

NAME VALUE

RING_0 ON(2000),IDLE(4000),R

RING_1 ON(800),OFF(400),ON(800),IDLE(4000),R

100ms

400ms

200ms

4000ms

200ms

300ms

4000ms

400ms

200ms

100ms

300ms

200ms

1 cycle