2103 Modem Module
Section 4 Modbus Protocol

4-6

4.6 Register Specifications

All numbers in the Modbus registers are stored most significant
byte first. If the polling device has a byte ordering of least signif-
icant byte first (an Intel-based PC, for example), the bytes will
need to be reversed after they are received.

The Modbus ASCII address is used to index the data by modules.

Modbus ASCII address 1 contains information related to the site.
The first register contains a 16-bit integer count of the number of
modules that have data to report. The maximum number of
modules that can be supported is 4.

Modbus ASCII addresses 2 through the number of modules plus
1 contain data from the individual modules.

The Modbus ASCII addresses will be sorted by the model
number, and then by module name, which is entered by the user
through Flowlink. This allows the user to control the ordering of
the addresses and easily predict what data will be in specific reg-
isters.

Every measured parameter has a corresponding status and mea-
surement time that are updated with each measurement.

The maximum number of supported measurements from all
modules in the system is 28.

The Modbus registers are assigned within 30 seconds after the
2100 module is powered up. To conserve power for the users who
do not use Modbus communications, no Modbus registers will be
updated with sensor readings until a Modbus master communi-
cates with the 2100 module.

The register definitions for the Site Information device (Modbus
ASCII address 1) are in Table 4-1 below:

Table 4-1 Modbus ASCII Address 1 Register Definitions

Register

Number(s)

Name

Data type

Units

Read/Write

1

Number of

modules (N)

(1-4)

16 bit integer

None

Read

2-20

Site name

38-byte string

None

Read