Fan Size 27”
Wheel Dia.
27.0 inches
686 mm
Inlet Area
5.20 square feet
0.483 m
2
Outlet Area
4.54 square feet
0.422 m
2
Tip Speed
7.07 x RPM
2.155
ft./minute
m/minute
Minimum Fan RPM (Without VFRB Option)
Motor
Minimum Fan RPM
1800 RPM
437
1200 RPM
291
Performance
Data
Q Fan and
Super Q II
Size 27
Pressure Class Limits
Class
Maximum RPM
I
1610
II
2160
III
2908
Table P-5 — Size 27 Q-Fan
CFM
Out-
Total Static Pressure
Std.
let
1
/
4
”
3
/
8
”
1
/
2
”
5/
8
”
3
/
4
”
1”
1
1
/
4
”
1
1
/
2
”
1
3
/
4
”
2”
Air
Vel.
RPM
BHP
RPM BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP RPM
BHP
3000
660
510
0.2
559
0.3
607
0.3
657
0.4
3500
770
564
0.2
607
0.3
649
0.4
690
0.5
731
0.6
4000
881
623
0.3
658
0.4
697
0.5
734
0.6
769
0.7
842
0.9
918
1.1
4500
991
684
0.4
715
0.5
747
0.6
781
0.7
815
0.8
878
1.0
943
1.2
1011
1.5
5000 1101
746
0.5
775
0.6
803
0.7
832
0.8
863
0.9
923
1.1
979
1.4
1038
1.6
1098
1.9 1160
2.2
5500 1211
810
0.6
836
0.7
862
0.8
887
0.9
914
1.0
970
1.3
1023
1.5
1075
1.8
1127
2.1 1182
2.4
6000 1321
874
0.7
898
0.8
922
1.0
945
1.1
969
1.2
1020
1.4
1070
1.7
1119
2.0
1166
2.3 1214
2.6
6500 1431
939
0.9
961
1.0
983
1.1
1005
1.2
1027
1.4
1072
1.6
1119
1.9
1165
2.2
1210
2.5 1253
2.9
7000 1541
1005
1.1
1026
1.2
1046
1.3
1067
1.4
1087
1.6
1127
1.9
1170
2.2
1214
2.5
1256
2.8 1298
3.1
7500 1651
1071
1.3
1090
1.4
1109
1.5
1129
1.7
1148
1.8
1185
2.1
1224
2.4
1264
2.7
1305
3.1 1345
3.4
8000 1762
1138
1.5
1156
1.6
1174
1.8
1191
1.9
1209
2.1
1245
2.4
1280
2.7
1317
3.0
1355
3.4 1393
3.7
8500 1872
1205
1.7
1221
1.9
1238
2.0
1255
2.2
1272
2.4
1306
2.7
1338
3.0
1372
3.4
1407
3.7 1443
4.1
9000 1982
1272
2.0
1287
2.2
1303
2.4
1319
2.5
1335
2.7
1367
3.0
1399
3.4
1430
3.7
1462
4.1 1495
4.5
9500 2092
1339
2.4
1354
2.5
1369
2.7
1384
2.9
1399
3.0
1429
3.4
1459
3.8
1489
4.1
1518
4.5 1549
4.9
10000 2202
1406
2.7
1420
2.9
1435
3.1
1449
3.2
1463
3.4
1492
3.8
1521
4.2
1549
4.6
1577
5.0 1605
5.4
10500 2312
1474
3.1
1487
3.3
1501
3.5
1515
3.6
1528
3.8
1555
4.2
1583
4.6
1610
5.0
1637
5.5 1663
5.9
11000 2422
1541
3.5
1554
3.7
1567
3.9
1580
4.1
1593
4.3
1619
4.7
1645
5.1
1671
5.5
1697
6.0 1723
6.4
11500 2533
1609
4.0
1622
4.2
1634
4.4
1646
4.6
1659
4.8
1684
5.2
1709
5.6
1734
6.1
1758
6.5 1783
7.0
12000 2643
1677
4.5
1689
4.7
1701
4.9
1713
5.1
1725
5.3
1748
5.8
1772
6.2
1796
6.7
1820
7.1 1844
7.6
12500 2753
1745
5.0
1756
5.3
1768
5.5
1779
5.7
1791
5.9
1813
6.4
1836
6.8
1859
7.3
1882
7.8 1905
8.3
13000 2863
1813
5.6
1824
5.9
1835
6.1
1846
6.3
1857
6.5
1879
7.0
1901
7.5
1923
8.0
1945
8.5 1967
9.0
13500 2973
1881
6.3
1892
6.5
1902
6.7
1913
7.0
1923
7.2
1944
7.7
1966
8.2
1987
8.7
2008
9.2 2029
9.7
14000 3083
1949
7.0
1959
7.2
1969
7.4
1980
7.7
1990
7.9
2010
8.4
2031
8.9
2051
9.4
2072
10.0 2092
10.5
14500 3193
2017
7.7
2027
7.9
2037
8.2
2047
8.4
2057
8.7
2076
9.2
2096
9.7
2116
10.3
2136
10.8 2155
11.3
CFM
Out-
Total Static Pressure
Std.
let
2
1
/
4
”
2
1
/
2
”
3”
3
1
/
2
”
4”
4
1
/
2
”
5”
5
1
/
2
”
6”
6
1
/
2
”
Air
Vel.
RPM
BHP
RPM BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP RPM
BHP
6000 1321
1263
3.0
1313
3.3
6500 1431
1298
3.2
1342
3.6
1435
4.3
7000 1541
1338
3.5
1380
3.8
1463
4.6
1549
5.4
7500 1651
1384
3.8
1421
4.1
1498
4.9
1576
5.8
1657
6.6
1740
7.6
8000 1762
1430
4.1
1467
4.5
1538
5.3
1611
6.1
1684
7.0
1760
7.9
1837
9.0
8500 1872
1479
4.5
1514
4.9
1584
5.7
1650
6.5
1718
7.4
1787
8.4
1858
9.4
1931
10.4
9000 1982
1529
4.9
1563
5.3
1629
6.1
1694
7.0
1757
7.9
1821
8.9
1886
9.9
1953
10.9
2021
12.0 2090
13.2
9500 2092
1581
5.3
1613
5.7
1677
6.6
1739
7.5
1799
8.4
1859
9.4
1921
10.4
1982
11.5
2045
12.6 2110
13.7
10000 2202
1635
5.8
1665
6.2
1726
7.1
1786
3.0
1845
9.0
1901
9.9
1959
11.0
2017
12.0
2075
13.2 2135
14.3
10500 2312
1691
6.3
1719
6.7
1777
7.6
1835
8.6
1891
9.6
1948
10.6
2001
11.6
2056
12.7
2111
13.8 2166
14.9
11000 2422
1748
6.9
1774
7.3
1828
8.2
1885
9.2
1939
10.2
1993
11.2
2047
12.3
2097
13.4
2150
14.5 2202
15.7
11500 2533
1808
7.5
1832
7.9
1882
8.9
1936
9.8
1989
10.9
2041
11.9
2092
13.0
2143
14.2
2191
15.2 2241
16.4
12000 2643
1868
8.1
1890
8.5
1938
9.5
1988
10.5
2039
11.6
2090
12.7
2139
13.8
2189
14.9
2238
16.1 2284
17.2
12500 2753
1928
8.8
1951
9.3
1995
10.2
2042
11.3
2091
12.3
2140
13.4
2188
14.6
2236
15.8
2283
17.0 2330
18.2
13000 2863
1989
9.5
2011 10.0
2053
11.0
2098
12.1
2143
13.2
2191
14.3
2238
15.4
2284
16.6
2330
17.9 2375
19.1
13500 2973
2051
10.2
2072 10.8
2114
11.8
2155
12.9
2198
14.0
2242
15.2
2289
16.3
2333
17.5
2378
18.8 2422
20.1
14000 3083
2113
11.0
2133
116
2174
12.7
2213
13.8
2254
14.9
2296
16.1
2341
17.3
2384
18.5
2427
19.8 2470
21.1
14500 3193
2175
11.9
2195 12.5
2234
13.6
2274
14.8
2312
15.9
2352
17.1
2393
18.3
2436
19.5
2477
20.8 2519
22.1
15000 3303
2238
12.8
2257 13.4
2295
14.6
2333
15.8
2370
16.9
2408
18.1
2447
19.4
2487
20.7
2529
21.9 2569
23.3
15500 3414
2301
13.8
2320 14.4
2357
15.6
2394
16.6
2430
18.0
2466
19.2
2503
20.5
2541
21.8
2580
23.1 2620
24.4
16000 3524
2365
14.8
2383 15.4
2419
16.6
2455
17.9
2490
19.2
2524
20.4
2560
21.7
2596
23.0
2633
24.4 2673
25.7
16500 3634
2429
15.9
2446 16.5
2481
17.8
2516
19.0
2550
20.3
2585
21.7
2618
23.0
2653
24.3
2688
25.7 2724
27.1
17000 3744
2493
17.0
2510 17.6
2544
18.9
2578
20.3
2611
21.6
2645
22.9
2677
24.3
2710
25.6
2744
27.0 2779
28.5
17500 3854
2558
18.2
2574 18.9
2607
20.2
2640
21.5
2672
22.9
2705
24.3
2738
25.7
2768
27.0
2801
28.5 2835
29.9
CFM
Out-
Total Static Pressure
Std.
let
7”
7
1
/
2
”
8”
8
1
/
2
”
9”
9
1
/
2
”
10”
10
1
/
2
”
11”
11
1
/
2
”
Air
Vel.
RPM
BHP
RPM BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP RPM
BHP
10000 2202
2196
15.4
2258 16.7
2319
18.0
10500 2312
2223
16.2
2280 17.4
2339
18.6
2398
19.9
11000 2422
2255
16.9
2309 18.1
2363
19.4
2419
20.6
2475
22.0
2531
23.4
11500 2533
2292
17.6
2342 18.9
2393
20.2
2445
21.5
2498
22.9
2551
24.2
2605
25.6
2659
27.1
12000 2643
2331
18.5
2380 19.7
2428
21.0
2476
22.3
2526
23.7
2576
25.1
2627
26.6
2678
27.9
2730
29.4 2781
31.0
12500 2753
2374
19.3
2420 20.6
2466
21.9
2513
23.3
2558
24.6
2606
26.0
2654
27.5
2702
29.0
2751
30.4 2800
31.9
13000 2863
2420
20.4
2463 21.6
2507
22.9
2551
24.2
2596
25.6
2640
27.0
2685
28.5
2731
30.0
2777
31.5 2823
33.0
13500 2973
2466
21.4
2509 22.7
2552
24.0
2592
25.3
2635
26.7
2678
28.1
2721
29.5
2763
31.0
2807
32.6 2851
34.1
14000 3083
2513
22.4
2555 23.8
2597
25.1
2638
26.5
2677
27.8
2718
29.2
2759
30.7
2801
32.2
2841
33.7 2883
35.3
14500 3193
2561
23.5
2602 24.9
2642
26.3
2683
27.7
2723
29.1
2760
30.4
2800
31.9
2839
33.4
2879
34.9
15000 3303
2609
24.6
2650 26.0
2689
27.5
2729
28.9
2768
30.4
2807
31.9
2842
33.2
2881
34.7
15500 3414
2659
25.8
2698 27.2
2737
28.7
2776
30.2
2814
31.7
2852
33.2
2890
34.7
16000 3524
2711
27.1
2748 28.5
2786
30.0
2824
31.5
2861
33.0
2898
34.6
16500 3634
2763
28.4
2799 29.9
2836
31.4
2873
32.9
17000 3744
2814
29.9
2851 31.3
2887
32.8
17500 3854
2868
31.4
2902 32.9
Performance based on 0.075 lbs. per cubic foot density (air at 70 F and 29.92 Hg Bar). Performance shown is for installation Type B: free inlet, ducted outlet.
Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream.
When inlet vanes are used increase rpm 1 percent and brake horsepower 3 percent.
Fan tables cover part of fan operating range; fan curves show full operating range.