Fibre Uplink Port Specifications

The switch has a 100Base-FX optical fibre uplink port that
operates at the 1310nm optical wavelength for both the multimode
and singlemode models.

The fibre size used for multimode links is 50/125 or 62/125 micron.
The fibre size used for singlemode links is 8/125 or 9/125 micron.

The maximum distance between any two fibre optic devices is
determined by a number of factors including optical link loss, the
type and number of patch cords and joints in the link, the launch
power of the transmitter and the sensitivity of the receiver. These
variables make calculating the maximum working distance
between two converters quite difficult and so it is best to design
networks using optical loss budgets rather than using just working
distance.

Plug-In Fiber Ethernet

Module Type

Average

Launch

Power dB

Average

Power

Loss Budget

dBm

Average

Sensitivity

dB

Multimode Converter (SC)

-18

dB

12d

Bm

-30

dB

Multimode Converter (ST)

-18

dB

12

dBm

-30

dB

Multimode Converter (MT-RJ)

-16

dB

14

dBm

-30

dB

Singlemode Converter (SC)

-18

dB

12

dBm

-30

dB

Table 2 - Optical Specifications