INSTALLATION / OPERATION INSTRUCTIONS

A. The compressor is ready to operate. Plug in the

cooler.

B. Temperature control set at No. 4 position gives

refrigerators an approximate temperature of 35°F.

Allow unit to function several hours, completely

cooling cabinet before changing the control setting.

C. Excessive tampering with the control could lead to

service difficulties. Should it ever become necessary

to replace temperature control, be sure it is ordered

from your TRUE dealer or recommended service

agent.

D. Good air flow in your TRUE unit is critical. Be

careful to load product so that it neither presses

against the back wall, nor comes within four inches

of the evaporator housing. Refrigerated air off the

coil must circulate down the back wall.

NOTE

If the cooler is disconnected or shut off, wait five minutes before

starting again.
RECOMMENDATION

Before loading product we recommend you run your TRUE unit

empty for two to three days. This allows you to be sure electrical

wiring and installation are correct and no shipping damage

has occurred. Remember, our factory warranty does not cover

product loss!
REPLACEMENT PARTS

TRUE maintains a record of the cabinet serial number for your

cooler. If at any time during the life of your cooler, a part is

needed, you may obtain this part by furnishing the model number

and serial number to the company from whom you purchased

the cooler. Call Toll-Free: (800)-424-TRUE (Direct to Parts

Department). (800)-325-6152 (U.S.A. & Canada only) or call:

(636)-240-2400.

The temperature control is located are the back of the

unit. (See image 1).

TEMPERATURE CONTROL LOCATION

Image 1

SEQUENCE OF OPERATION

Temperature Control Sequence of Operation

When the cabinet is plugged the unit will start up in a defrost cycle. The evaporator fan is hard-wired and will

continue to run during this time. The cooler will stay in defrost for a minimum of 4 minutes or until the coil

temperature reaches at least 41˚F. The maximum time the cooler will be in defrost is 40 minutes. At the end of

the defrost cycle, there will be a 2 minute delay to allow any water to drip off of the evaporator coil. After this

time, the compressors will come on and the cooler should start to cool down. The compressors will run until the

temperature control is satisfied. Every 4 hours of compressor run time, the cooler will go into defrost and remain

in defrost until the coil temperature reaches 41˚F.

NOTE:

When the unit is first plugged in it will take at least 6 minutes

before the compressor starts.