Toro GROUNDSMASTER 345 User Manual

Page 51

Advertising
background image

TORO GM 345 / 325-D Hydraulics

Notes

________________________________________________________________________________________________________________

________________________________________________________________________________________________________________

________________________________________________________________________________________________________________

________________________________________________________________________________________________________________

________________________________________________________________________________________________________________

________________________________________________________________________________________________________________

________________________________________________________________________________________________________________

________________________________________________________________________________________________________________

________________________________________________________________________________________________________________

49

1. Testing charge flow.

Connect hydraulic flow meter.

Operate engine at 3200 RPM.

Restrict oil flow through flow tester. Should be able to read 1GPM at 700 PSI.


Low charge flow (charge pressure “OK”)


2. Possible

causes:

Leaking implement relief valve.

Worn drive pump.

Worn drive motor.

3. Performance

results:

Slow steering response.

Slow hydraulic response.

System overheating. (low oil cooler flow)

Advertising