Adjusting the Cutting Unit Lift

Rate

The cutting unit lift circuit is equipped with (3) adjustable

valves used to ensure the cutting units do not raise too

quickly and bang against lift stops. Adjust cutting units as

follows:

Center Cutting Unit

1. Locate valve behind access panel above operator’s

platform (Fig. 62).

2. Loosen setscrew on valve and rotate valve

approximately 1/2 turn clockwise.

3. Verify lift rate adjustment by raising and lowering

cutting unit several times. Readjust as required.

4. After desired lift rate is attained, tighten setscrew to

lock adjustment.

1

Figure 62

1. Center cutting unit adjustment valve

Outside Front Cutting Units

1. Locate valve on flow divider (under foot rest) (Fig. 63).

2. Loosen setscrew on valve. Rotate valve 1/2 turn

clockwise.

3. Verify lift rate adjustment by raising and lowering

cutting units several times. Readjust as required.

4. After desired lift rate is attained, tighten set screw to

lock adjustment.

1

Figure 63

1. Outside front cutting units adjustment valve

Rear Cutting Units

1. Raise hood and locate valve on left rear side of machine

(Fig. 64).

1

Figure 64

1. Rear cutting units adjustment valve

2. Loosen setscrew on valve and rotate valve

approximately 1/2 turn clockwise.

3. Verify lift rate adjustment by raising and lowering

cutting units several times. Readjust as required.

4. After desired lift rate is attained, tighten setscrew to

lock adjustment.