3 Hardware Commands

3.1 Turning ON the GE863-QUAD/PY

To turn on the GE863-QUAD/PY the pad ON# must be tied low for at least 1 second and then
released.
The maximum current that can be drained from the ON# pad is 0,1 mA.
A simple circuit to do it is:


NOTE: don't use any pull up resistor on the ON# line, it is internally pulled up. Using pull
up resistor may bring to latch up problems on the GE863-QUAD/PY power regulator and
improper power on/off of the module. The line ON# must be connected only in open
collector configuration.

NOTE: In this document all the lines that are inverted, hence have active low signals are
labeled with a name that ends with a "#" or with a bar over the name.

NOTE: The GE863-QUAD/PY turns fully on also by supplying power to the Charge pad
(provided there's a battery on the VBATT pads).





For example:

ON#

Power ON impulse

GND

R1

R2

Q1