6.2 MODEM SERIAL PORT 2 (Python Debug)


It is available on the following pins:

PIN #

NAME

DESCRIPTION

TYPE

25

TX_TRACE

TX Data

CMOS 2.8V

26

RX_TRACE

RX Data

CMOS 2.8V

6.3 RS232 level translation

In order to interface the Telit GE863-QUAD/PY with a PC com port or a RS232 (EIA/TIA-232)
application a level translator is required. This level translator must

• invert the electrical signal in both directions

• change the level from 0/3V to +15/-15V


Actually, the RS232 UART 16450, 16550, 16650 & 16750 chipsets accept signals with lower levels on
the RS232 side (EIA/TIA-562) , allowing for a lower voltage-multiplying ratio on the level translator.
Note that the negative signal voltage must be less than 0V and hence some sort of level translation is
always required.
The simplest way to translate the levels and invert the signal is by using a single chip level translator.
There are a multitude of them, differing in the number of driver and receiver and in the levels (be sure
to get a true RS232 level translator not a RS485 or other standards).
By convention the driver is the level translator from the 0-3V UART level to the RS232 level, while the
receiver is the translator from RS232 level to 0-3V UART.

In order to translate the whole set of control lines of the UART you will need:

• 5 driver

• 3 receiver

NOTE: The digital input lines working at 2.8VCMOS have an absolute maximum input
voltage of 3,75V; therefore the level translator IC shall not be powered by the +3.8V supply
of the module. Instead it shall be powered from a +2.8V / +3.0V (dedicated) power supply.
This is because in this way the level translator IC outputs on the module side (i.e. GE863-
QUAD/PY inputs) will work at +3.8V interface levels, stressing the module inputs at its
maximum input voltage.
This can be acceptable for evaluation purposes, but not on production devices.