Installation instructions

Important - safety

requirements

This appliance is suitable for installing on

gas I2ELL and I2E.

To install the appliance on gas supply of I2E

the hotplate injectors must be changed to

those supplied with the appliance.

INJECTOR MARKING

I2ELL

INJECTOR MARKING

I2E

RHF

074

070

RHR

106

096

LHF

106

096

LHR

133

119

Check that this model is suitable for the type

of supply available. This appliance must be

installed and or serviced by a competent

person in accordance with the local Gas

Safety/Electrical requirements.

This appliance must be

installed by a qualified

electrician / competent person.

Safety may be impaired if

installation is not carried out in

accordance

with

these

instructions.

Before connecting the appliance

make sure that the voltage of

your electricity supply is the

same as that indicated on the

rating plate. This is situated on

the lower front frame of the

appliance and can be seen upon

opening the door. Alternatively

the rating plate may also be

found on the back or top of

some

models

(where

applicable).
Do not alter the electrical

circuitry of this appliance.

Provision for ventilation

This appliance is not connected to a

combustion products evacuation device. It

shall be installed and connected in

accordance with the current installation

regulations. Particular attention shall be

given to the relevant requirements regarding

ventilation.

The room containing the appliance should

have an air supply in accordance with local

requirements. All rooms require an

openable window or equivalent and some

rooms will require a permanent vent as well.

For room volumes up to 5m

3

an air vent of

100cm

2

is required: for room volumes

between 5m

3

and 10m

3

an air vent of 50cm

2

is required. If the room has a door that

opens directly to the outside, no air vent is

required. For room volumes that exceed

11m

3

no air vent is required. If there are

other fuel burning appliances in the same

room, local requirements should be

consulted to determine the requisite air vent

requirements.

Prolonged intensive use of the appliance

may call for additional ventilation, for

example opening a window, or more

effective ventilation, for example increasing

the level of mechanical ventilation where

present.

Moving your appliance

You may damage some soft or badly fitted

floor coverings when you move the

appliance. The floor covering under the

appliance should be securely fixed so it does

not ruck up when you move the appliance

across it. Alternatively you could remove the

floor covering. This appliance is heavy and

care must be taken when moving it. Do not

try to move the appliance by pulling the door

handles.