Connecting to gas supply

This appliance is designed to be installed

with an appliance flexible connection only.

Supply piping should not be less than R

3

/8.

Connection is made to the Rc ½ (½” B.S.P.)

female threaded entry pipe located just

below the hotplate level on the rear left hand

side of the appliance.

NOTE: ONLY LIQUID

SEALANTS TO BE USED WHEN INLET

GAS PIPE IS FITTED I.E.: DO NOT USE

P.T.F.E. SEALANT TAPE.
Carry out a gas tightness test after

connecting to the gas supply. The gas

bayonet connector must be fitted in the

shaded area indicated in Fig.2. Take into

account that it must be possible to pull the

appliance forward sufficiently. Ensure the

hose does not become trapped when

pushing the appliance into position.
IMPORTANT: FLEXIBLE TUBING USED

MUST COMPLY WITH BS.669 CURRENT

EDITION.

Fitting the stability bracket

It is recommended that if the appliance is to

be installed with a flexible supply pipe, a

stability bracket be fitted and is available

from your supplier (see Important Safety

Requirements). These instructions should

be read in conjunction with any leaflet

packed with the stability bracket.

1. Place the appliance in its intended

position and level appliance.

2. Mark off 300mm from the left hand side

of the appliance as shown in dimension

'A', Fig

3a. This is the centre line of the

fixing bracket.

3. Draw a line 100mm from the front edge

of the feet (see Fig.3a) and remove

appliance from its position. Mark off

dimension 'B' (see Fig.3a) back from this

line on the centre line of the bracket

to

locate

the front edge of the lower

bracket.

48

7m

m

(B

)

300mm

100mm

20mm

(A)

(C)

Fig.3a.

Fig.3b.

25

0

85

0

45

0

70

0

400

50 100

Fig.2.