Chapter 6 firmware upgrade procedure – Trango Broadband TrangoLINK-45TM User Manual

Page 39

Advertising
background image

Firmware Upgrade Procedure

Firmware File Names

Trango Broadband Wireless — TrangoLINK-45

page 39

Chapter 6 Firmware Upgrade Procedure

Trango Broadband Wireless will from time to time release firmware upgrades for the TrangoLINK-45 series radios. The
latest released firmware can be downloaded from

http://www.trangobroadband.com/support/downloads.htm

.


Firmware releases consists of two files: Main image firmware and Web (HTTP interface) firmware.

Firmware File Names

Firmware files are released in the format shown below. This example consists of main image and web firmware versions
2p0r1.

Main Image:

p5055m_main_2p0r1D07061104_Pupgrade

Firmware

Version:

2p0r1D07061104

File

Size:

2,107,904

bytes


Web

p5055m_web_1p3D07051701_Pupgrade
File Size: 143,872 bytes

Firmware Upgrade Password

The firmware filenames include the upgrade password (the characters after the ‘_P’ in the file name) The default
upgrade password in the TrangoLINK-45 radios is upgrade. Users may change the upgrade password within the radios
using the password upgrade command. Firmware release files from Trango Broadband Wireless will always be names
with the default upgrade password of upgrade. If the user changes the upgrade password in the radio, then the firmware
file name must be changed as well in order to upgrade the radios.

Upgrade Procedure

1. Place firmware files in easily accessible path in your computer.
2. In order to provide the most stable wireless conditions possible during the upgrade process it is recommended to

set the radio speed to the minimum (6 Mbps) in both the MU and RU. Turn autorateshifting off during the
upgrade.

3. Turn on the radio’s tftp daemon
4. From computer’s command prompt, tftp the firmware file into the radio using binary mode.
5. After file is successfully tftp’d to the radio, the radio will automatically reboot itself and load the new firmware

IMPORTANT: DO NOT POWER CYCLE OR INTERUPT THE REBOOT PROCESS IN ANY MANNER.
WAIT AT LEAST THREE MINUTES TO ENSURE AUTOMATIC REBOOT COMPLETION. LOSS OF
POWER DURING THE REBOOT SEQUENCE WILL RESULT IN A CORRUPTED/INCOMPLETE
FIRMWARE LOAD WHICH WILL REQUIRE REFLASHING AT THE FACTORY.

6. Repeat process for other radio
7. Repeat process for web file.

Example 1 Upgrade main image firmware to 1.0a6

FROM RADIO TELNET SESSION

Welcome to Trango Broadband Wireless, TrangoLINK-45 PtP-P5055M 2p0r1D07061104
Password:
Login as read/write.
#> tftpd on

Advertising