GS v 0 m xL xH yL yH d1...dk

[Name]
[Format]

[Range]

[Description]

[Details]

[Example]

Printing of raster bit image
ASC II GS v 0 m xL xH yL yH d1...dk
Hex 1D 76 30 m xL xH yL yH d1...dk
Decimal 29 118 48 m xL xH yL yH d1...dk
0

m 3, 48 m 51, 0 xL 255, 0 xH 255,

0

yL 255, 0 yH 8, 0 d 255,

k=(xL+xH x 256) x (yL+yH x 256), however, k 0
Prints raster bit images in mode m .

xL, xH specify the number of data in horizontal direction of the bit
image to (xL+xH x 256) bytes.
yL, yH specify the number of data in vertical direction of the bit
image to (yL+yH x 256) bytes.
In STANDARD MODE, this command is valid only when there is no
print data in the print buffer.
Any of the print modes (Character size, emphasis, double strike,
inverting, underlining, back-to-white reversing, etc.) does not
affect the raster bit image.
If the print area specified by GS L and GS W is narrower than a
minimum width, the print area for that line only is extended to the
minimum width. The minimum width is one dot in NORMAL
MODE (m=0, 48) and DOUBLE HEIGHT MODE (m=2,50), and 2
dots in DOUBLE WIDTH MODE (m=1, 49) and QUADRUPLE SIZE
MODE (m=3, 51).
Any part of data that is out of the print area is only read and
discarded in units of dot.
The setting of ESC a (Aligning characters) are also valid for the
raster bit image.
If this command is executed during macro definition, the macro
definition is suspended, and the processing of the command
starts. The macro is left undefined.

d denotes defined data. Dots to be printed are specified as
1

and those not to be printed as

0

.

When xL+xH x 256= 64:

0,48
1,49
2,50
3,51

NORMAL MODE

DOUBLE WIDTH MODE

DOUBLE HEIGHT MODE

QUADRUPLE SIZE MODE

Dot Density in

Vertical Direction

203 DPI
203 DPI
101 DPI
101 DPI

Dot Density in

Horizontal Direction

203 DPI
101 DPI
203 DPI
101 DPI

Mode Name

m

MSB

LSB

(XL + xH x 256)x 8 dot=512 dot

YL + yH x 256 dot

1

2

3

62

63

64

65

66

67

126

127

128

K-2

K-1

K

7

6 5

0

4 3

2

1

25

GS h n

[Name]
[Format]

[Range]
[Description]

[Details]
[See Also]

Define downloaded bit image
ASCII GS h n
Hex 1D 68 n
Decimal 29 104 n
1

n

255

Selects the height of the bar code.
n specifies the number of dots in the vertical direction.
N = 162
GS k

(1) GS k m d1...dk NUL
(2) GS k m n d1...dn

[Name]
[Format]

[Range]

[Description]

[Details]

Print the bar code
(1) ASCII GS V m d1...dk Nul
Hex 1D 6B m d1...dk 00
Decimal 29 107 m d1...dk 0
(2) ASCII GS k m n d1...dn
Hex 1D 6B m n d1...dn
Decimal 29 107 m n d1...dn
(1) 0 m 6 (k and d depends on the bar code system used)
(2) 65 m 73 (n and d depends on the bar code system used)
Selects a bar code system and prints the bar code. m selects a bar
code system as follows:

For (1):
This command ends with a NUL code.
When the bar code system used is JAN13 (EAN13), the printer
prints the bar code after receiving 13 bytes bar code data and
processes the following data as normal data.
When the bar code system used is JAN8 (EAN8), the printer prints
the bar code after receiving 8 bytes bar code data and processes
the following data as normal data.

CODE39

m

2
3

Bar Code System

JAN13 (EAN13)

JAN 8 (EAN8)

Number of Characters

12

k

13

7

k

8

Remarks
48

d

57

48

d

57

48

d 57, 65 d 90,

32, 36, 37, 43, 45, 46, 47

4

1

k

For (1) :

For (2) :

m

67
68

73

Bar Code System

JAN13 (EAN13)

JAN 8 (EAN8)

CODE128

Number of Characters

12

k

13

7

k

8

2

k 255

Remarks
48

d

57

48

d

57

48

d 57, 65 d 90,

32, 36, 37, 43, 45, 46, 47
0

d

127

69

CODE39

1

k 255

26

RP-3180 USER'S MANUAL