IONPS-A, AC Power Module

4

Tech Support: 1-800-260-1312 – International: 00-1-952-941-7600 – (24 hours)

Figure 1: Power Module Components

Description

Transition Networks’ IONPS-A, AC Power Module can deliver power or provide
optional, redundant AC power to an ION219-A chassis. See the ION219-A chassis
manual #33421. You can download the manual @

www.transition.com

, then click on

Product/Product Finder.

Power Module component identification

See Figure 1:

1

Fans (two fans exhaust warm air from the IONPS-A, AC Power Module)

2

Power LED (ON green when powered up)

3

ON/OFF switch, when in the ON position power is supplied to the ION chassis

4

Fuse (inline AC)

5

Handle

6

AC Power Receptacle for an AC power plug

7

Dry Contact Relay (optional)

Note: The IONPS-A, AC Power Module has instant failover capability.

1

5

3

7

4

1

2

6

[email protected] – Click the “Transition Now” link for a live Web chat.

5

Installation

I

MPORTANT

All installation and service must be performed by qualified personnel only.

Read, understand, and follow all CAUTION and WARNING notices, instructions
marked on the product, including in this manual.

The IONPS-A, AC Power Module can replace an existing IONPS-A, AC Power
Module or it can be installed as the redundant Power Module in an AC powered
ION219-A chassis.

CAUTION: While installing or servicing the Power Module, wear a grounding
device and observe all electrostatic discharge precautions. Failure to observe this
caution could result in damage or failure of the Power Module.

Description — continued

Notices

The IONPS-A, AC Power Module must be installed by qualified technical
personnel only. Transition networks assumes no responsibility for the improper
installation, set up, or use of the IONPS-A, AC Power Module.

The information in this user’s guide is subject to change. For the most up-to-date
information, see the user’s guide on-line to download the current version of the
manual at

www.transition.com

under Products.

Power module redundancy

The IONPS-A, AC Power Module includes Instant Fail-Over (IFO) circuitry that
provides the capability for the primary Power Module to power the chassis backplane
while the auxiliary Power Module is in ‘hot’ standby mode. If the IFO circuitry detects
the loss of primary power, the auxiliary Power Module instantly provides power to the
chassis backplane. When primary power is restored, the IFO circuitry places the
auxiliary Power Module in ‘hot’ standby mode. The chassis primary Power Module is
located in the left slot of the chassis as viewed from the rear. The chassis auxiliary
Power Module is located in the right slot of the chassis as viewed from the rear. A
single Power Module placed in either location can power the chassis backplane.

Note: The IONPS-A, AC Power Modules DO NOT load share.