Installation — continued – Transition Networks 33423.A User Manual

Page 4

Advertising
background image

IONPS-A, AC Power Module

6

Tech Support: 1-800-260-1312 – International: 00-1-952-941-7600 – (24 hours)

Installing an optional Power Module into the ION chassis

WARNING: Do not connect the Power Module to an external power source before
installing it into the chassis. Failure to observe this warning could result in an
electrical shock.

Note: The Power Module is hot swappable (i.e., swapped while the chassis is in

operation) provided the ON/OFF switch of the Power Module is in the OFF
position, and it has been disconnected from its external power source.

To install the Power Module in the ION chassis, do the following:

Note: The procedure is the same for installing the Power Module into either slot.

1. Push the Power Module ON/OFF switch to the OFF position. See Figure 2.

Power Module
Switch OFF Position

Figure 2: Power ON/OFF Switch

Installation — Continued

[email protected] – Click the “Transition Now” link for a live Web chat.

7

3. Remove the slot cover from the right chassis slot and keep the two screws. See

Figure 4.

2. If necessary, remove the grounding hardware from the chassis before installing or

removing the Power Module. See Figure 3.

Installing an optional Power Module into the ION chassis — continued

Installation — Continued

S lot

Cov

er

Screws

Compression Lugs

Kepsnuts

Chassis

Grounding

Posts

(Not Provided )

(provided)

Figure 4: Chassis Slot Cover

Figure 3: Chassis Grounding Hardware

Advertising