6

INDOOR UNIT FIXING

7

DRAINAGE

1. Pass the pipe through the hole in the wall, and hook the

indoor unit on the installation plate at the upper hooks.

2. Swing the indoor unit to right and left to confirm that it is firmly

hooked up on the installation plate.

3. While pressing the indoor unit onto the wall, hook it at the

lower part on the installation plate. Pull the indoor unit toward
you to confirm that it is firmly hooked up on the installation
plate.

• For detaching the indoor unit from the installation plate, pull the

indoor unit toward you while pushing its bottom up at the
specified parts.

CAUTION

Arrange the drain pipe for proper drainage from the unit.

Improper drainage can result in dew- dropping.

This air conditioner has the structure designed to drain water collected
from dew, which forms on the back of the indoor unit, to the drain pan.

Therefore, do not store the power cord and other parts at a height
above the drain guide.

1. Run the drain hose sloped downwards.

NOTE

• Hole should be made at a slight downward

slant on the outdoor side.

2. Put water in the drain pan and make sure that

the water is drained out of doors.

3. When connecting extension drain hose,

insulate the connecting part of extension
drain hose with shield pipe.

50 mm
or more

Do not put the
drain hose end
into water.

Do not put the
drain hose end in
the drainage ditch.

Do not form the drain hose
into a wavy shape.

Do not rise the drain hose.

Extension drain hose

Inside the
room

Drain hose

Shield pipe

Wall

Drain
guide

Space for pipes

Hook

1

Installation plate

Hook here

Press

(unhook)

1

2

Push

Push