New check code

1. Difference between the new check code and the current system

The displaying method of the check code changes in this model and after.

<Display on wired remote controller>

• [

] goes on.

• [UNIT No.] + Check code + Operation lamp (Green) flash

<Display on sensor part of wireless>

• Block display of combination of [

] [

] [

]

<Display on indicater on wireless remote controller
receiver part>

• Unit No. and check code are displayed.

• In a case of error with auxiliary code, check code and

auxiliary code are displayed alternately.

 →

Used characters

Characteristics of code classification

Block display

Check code in current system

Hexadecimal notation, 2 digits

Few classification of communication/incorrect setup system

Indoor P.C. board, Outdoor P.C. board, Cycle, Communication

New check code

Alphabet + Decimal notation, 2 digits

Many classification of communication/incorrect setup system

Communication/Incorrect setup (4 ways), Indoor protection,
Outdoor protection, Sensor, Compressor protection, etc.

Display

A

C

E

F

H

J

L

P

Classification

Unused

Central control system error

Communication system error

Each sensor error (Failure)

Compressor protective system error

Unused

Setup error, Other errors

Protective device operation